- Pump performance and acceptance testing: Normal measured flow
- 3–2,300 m³/h; flow-meter accuracy class ±0.3%; up to 3,000 m³/h only at reduced accuracy
- Pump performance and acceptance testing: Normal motor power
- 1–315 kW; approximately 500 kW requires the special customer-VFD and manual/approximate power-meter arrangement
- Pump performance and acceptance testing: Test medium and volume
- Water at approximately 20 °C in a 150,000 L closed loop
- Pump performance and acceptance testing: Bench connections
- Inlet DN 20–500; outlet DN 15–500
- Pump performance and acceptance testing: Normal maximum speed
- 3,600 rpm; higher speed requires a separately agreed test
- Pump performance and acceptance testing: Normal pump-plus-motor mass
- Up to 5,000 kg; heavier units need separate handling
- Pump performance and acceptance testing: NPSHr limitation
- Values below approximately 2 m liquid column cannot be established precisely on this bench
- Pump performance and acceptance testing: Electrical supply
- 380–420 V at 50 Hz or 440–480 V at 60 Hz; 690 V needs rental equipment